Solar load calculator / Battery tools

Solar battery charging time calculator

Estimate solar recharge while appliances keep running. See battery charge, daytime and overnight consumption, charging limits and energy shortfalls across a repeating daily schedule.

Example settings. Enter your equipment values or carry an appliance list from the solar load calculator.

Scheduled energy covered in the modelView results ↓

Your battery

Chemistry presets are editable planning assumptions. Manufacturer data takes priority.

Appliances to power

Set each appliance’s daily start time and operating hours. Schedules repeat every day and can cross midnight. Use measured average watts for cycling loads.

Appliance 1

Solar and timing

Losses and equipment limits

Enter the ratings of your equipment. Missing ratings are not interpreted as proof that the equipment is suitable.

3-day solar and battery plan

Scheduled energy covered

The model supplies the entered schedule within its continuous-power and energy assumptions. Review starting and equipment limits below.

Recovery after first use23.3 hoursFrom plan start to 100% charge; “not reached” means within these 3 days.
First energy shortfallNone in this planElapsed time from the start, based on 15-minute steps
Lowest battery charge24.3%Ends at 100%
Solar at the DC bus12 kWhTotal for 3 days, after entered PV losses and controller clipping

Power and starting checks

Assumes all selected loads are on together and the largest 1 start coincide. Daily energy coverage does not certify a start or an installation.

Estimated AC start demand
300 W
DC bus demand with all loads on
343.33 W
Stored energy above reserve
3.84 kWh

Not checked: inverter continuous output, inverter surge output, battery discharge output. Enter these in “Losses and equipment limits”.

Battery charge through the plan

Starts at 18:00. Each day below is the next 24 hours from that start, not a calendar day.

0%50%100%0 h72 h

Blue: modelled charge. Dashed amber: selected reserve.

Daily energy balance (kWh) and battery charge
DaySolarLoadUnservedEnd charge
1430100%
2430100%
3430100%
Appliance energy delivered
9 kWh
Conversion losses / inverter standby
2.12 / 0.72 kWh
Unused solar after controller
0.16 kWh
Solar clipped at controller limit
0 kWh
  • Charging near full can taper or enter absorption. The energy-only time to target can be optimistic.
  • A zero charge-power rating means that limit is not checked. Enter manufacturer limits to model charge clipping.

Compare one change

20% lower appliance watts; all other inputs and power ratings stay the same.

Original scenario compared with one change
MeasureOriginalChanged
Continuous battery runtime10.6 hours13.2 hours
Unserved appliance energy0 kWh0 kWh
Battery charge at plan end100%100%

A larger battery starts with more stored energy at the same charge percentage. It can delay a shortfall without fixing a continuing daily energy deficit. This comparison does not verify an equipment upgrade.

Inputs for this estimate

Energy model v1. Values below are included when you print.

Battery and present capacity
4.8 kWh nominal · 48 V · 100% · lifepo4
Start / reserve / solar target
100% / 20% / 100%
Inverter / discharge / charge efficiency
90% / 95% / 95%
Inverter standby (always on)
10 W DC
Inverter continuous / surge rating
Not entered / Not entered
Battery DC discharge / charge limit
Not entered / Not entered
Panels / peak sun hours / PV losses
1,000 W / 5 h / 20%
Controller output limit
Not entered
Daylight / plan starts / duration
06:00 for 12 h / 18:00 / 3 days
Solar availability
available
Appliances included in this result
ApplianceLoadDaily schedule
Essential appliances300 W × 1 AC
1× start
20:00 · 10 h

Charging time while appliances are running

Panel power is shared between the active loads and battery charging. The planner first applies PV/controller conversion losses and the controller output limit. It supplies the active loads, then sends any surplus to the battery within its charging-power limit and target charge.

When solar is insufficient, the battery supplies the deficit until its reserve or discharge-power limit is reached. Remaining appliance demand is reported as unserved energy. No grid or generator supply is assumed.

Worked example: why daytime consumption changes charging time

A 1,000 W array with 5 peak sun hours and 20% PV/controller conversion losses supplies 4,000 Wh/day at the DC bus before controller clipping. If 2,000 Wh of daytime AC appliances run while solar is available, a 90% efficient inverter requires approximately 2,222 Wh for those appliances.

That leaves at most 1,778 Wh of solar input for charging before standby and other limits. At 95% charging efficiency, approximately 1,689 Wh can be stored. This simplified energy example assumes suitable overlap; the planner’s schedule and power limits can reduce the amount further.

Why a bigger battery may still run down

If daily solar energy remains below daily consumption and conversion losses, increasing storage alone does not remove that continuing deficit. The comparison keeps the entered charge percentage constant, so a larger battery also begins with more stored energy. Look at the full simulated period and the ending charge, not just the first night.

How to enter a realistic scenario

  1. Enter nominal battery capacity, present capacity, starting charge, reserve and charging target.
  2. Add appliances and set their daily operating windows. Imported appliance hours are preserved, but start times are assumptions that you must review.
  3. Enter array watts, local seasonal peak sun hours and losses. Confirm whether solar is actually available to the backup system.
  4. Enter controller, battery and inverter limits. A zero rating means “not checked”.
  5. Compare reduced load, added panels or added battery capacity and inspect unserved energy and ending charge.

What the solar recharge model includes

The model uses 15-minute energy steps and repeats the same daily appliance schedule and smooth daylight profile for one to seven days. Daily PV energy before controller clipping equals array watts × peak sun hours × (1 − PV loss fraction). The daylight shape distributes that energy across the entered solar window; it is an assumption, not measured irradiance.

Losses are applied once along each relevant energy path. Direct solar-to-load energy does not incur battery charge/discharge losses. Battery charging uses a one-way charge efficiency, and discharge uses a separate one-way discharge efficiency. Controller limits apply before loads and storage; battery charging limits apply to surplus after loads.

Charging stops at the entered target. “First time to target” is elapsed time from the selected start; if the battery starts at or above target, the result instead shows its first recovery to target after discharging below it.

Common solar-charging questions

Are peak sun hours the same as daylight hours?

No. Peak sun hours describe daily solar energy as equivalent hours at reference irradiance. Daylight duration describes the clock-time window in which the model distributes that energy. Enter a local seasonal resource value rather than treating the example as a forecast.

Will my grid-connected solar recharge a battery during a blackout?

Only if the equipment and configuration support it. Some systems shut down solar production during an outage, even if the battery can supply backup loads. Choose “Not confirmed” to exclude solar until you have checked.

Why might actual full charging take longer?

Near-full absorption, current taper, cell balancing, battery protection, temperature and changing sunlight are not fully described by an energy-only model. A calculated 100% target is particularly uncertain.

Does scheduled energy coverage certify my inverter or wiring?

No. The continuous-energy model caps power but does not simulate an inverter tripping and restarting, short startup pulses, surge duration, wiring, protection or compatibility. Review the separate starting check and manufacturer requirements.

Can I use hourly weather data or a local solar forecast?

This release uses manually entered solar resource and an illustrative daily shape. It does not retrieve weather or connect to your inverter. A later location-based model would be a separate feature.

Check continuous battery runtime without solar.

Method and sources

These tools use an energy-balance model with editable assumptions. The sources below explain battery monitoring, solar-and-storage behaviour and backup-system limitations; they do not certify this calculator or your installation.

Existing solar sizing methodology · Engineering limitations · About the site · Report a calculation issue