2,000 units • panels • inverter • battery

Solar System for 2,000 Units per Month

A home or shop using 2,000 units a month needs about 15.2 kW of solar at the national average of 5.3 peak sun hours. Check your city below, then adjust the wizard for your panel size and backup needs.

  • Free
  • No signup
  • Runs in your browser
  • Assumptions you can edit

Find it on your electricity bill as “units consumed”. Use an average of several months.

System type
Optional: estimate payback

Divide the total of a recent bill by its units to get your average rate. The estimate assumes the solar units replace grid units at that rate. Under net billing, exported units are credited at a lower buyback rate, so savings can be smaller.

Your solar estimate

Solar array needed
15.24
kW
550 W panels
28
panels
Installed array
15.4
kWp
Inverter size
13
kW
Monthly production
2,022
kWh
Roof area
83
m² (889 ft²)

Panels alone at the current market rate (PKR 41/W): about PKR 631,400. This excludes inverter, battery, mounting, cables, installation and approvals.

Uses 5.3 peak sun hours, 14% system losses and 96% inverter efficiency (82.6% combined), sized to offset 2,000 units a month on average. Summer output is higher and winter lower than this average.

Quick answer for 2,000 units

Array
15.2 kW
Panels (550 W)
28
Inverter
13 kW
Roof area
83 m²

Calculation: 2000 ÷ 30 = 66.7 units per day; 66.7 ÷ (5.3 × 0.8256) = 15.24 kW. The 0.8256 factor combines 14% system losses with 96% inverter efficiency.

Panels needed for 2,000 units by panel size

PanelPanelsInstalled array
450 W3415.3 kWp
550 W2815.4 kWp
585 W2715.8 kWp
620 W2515.5 kWp
700 W2215.4 kWp

2,000 units: solar size by city

Sunnier cities need a smaller array for the same units. Peak sun hours are planning averages from the site's city dataset, not measured values.

CitySun hoursArray550 W panels
Abbottabad4.816.8 kW31
Attock5.315.2 kW28
Bahawalpur5.714.2 kW26
Chakwal5.315.2 kW28
Charsadda5.215.5 kW29
Dera Ghazi Khan5.614.4 kW27
Dera Ismail Khan5.614.4 kW27
Faisalabad5.315.2 kW28
Gilgit4.617.6 kW32
Gujranwala5.115.8 kW29
Gujrat5.115.8 kW29
Gwadar5.614.4 kW27
Hyderabad5.514.7 kW27
Islamabad5.115.8 kW29
Jhang5.415 kW28
Jhelum5.215.5 kW29
Karachi5.415 kW28
Kasur5.215.5 kW29
Khuzdar5.714.2 kW26
Kohat5.415 kW28
Lahore5.115.8 kW29
Larkana5.614.4 kW27
Mardan5.215.5 kW29
Mianwali5.514.7 kW27
Mirpur5.115.8 kW29
Mirpurkhas5.514.7 kW27
Multan5.614.4 kW27
Muzaffarabad4.717.2 kW32
Nawabshah5.714.2 kW26
Nowshera5.315.2 kW28
Okara5.315.2 kW28
Peshawar5.315.2 kW28
Quetta5.813.9 kW26
Rahim Yar Khan5.714.2 kW26
Rawalpindi5.115.8 kW29
Sahiwal5.415 kW28
Sargodha5.415 kW28
Sheikhupura5.215.5 kW29
Sialkot516.1 kW30
Skardu4.617.6 kW32
Sukkur5.614.4 kW27
Swat4.916.5 kW30
Turbat613.5 kW25

Net metering vs net billing in Pakistan

In February 2026 NEPRA replaced net metering with a net-billing model for new solar consumers. Under net billing, units you export are credited at a lower buyback rate than the price you pay for imported units, so using more of your own solar output directly (daytime loads, or a battery) is worth more than exporting it. Reports put agreements signed before 9 February 2026 outside the new rules, and sources differ on the exact new rate. Read the report.

Rules and rates have been revised more than once, so confirm the current buyback rate and eligibility with NEPRA or your distribution company before you decide on system size or a battery.

Frequently asked questions

What size solar system do I need for 2000 units per month?

About 15.2 kW of panels at 5.3 peak sun hours. Depending on the city (4.6 to 6 sun hours in the dataset) it ranges from 13.5 kW to 17.6 kW. Installers usually round up to the next standard size.

How many solar panels are needed for 2000 units?

28 panels of 550 W (15.4 kWp installed) at the national average. With 620 W panels it is 25 panels; with 450 W panels it is 34.

What inverter size suits a 2000-unit solar system?

Around 13 kW, from the array size divided by a typical DC/AC ratio of 1.2. The inverter must also cover your peak simultaneous load and motor starting surge, so check your appliances with the load calculator.

How much roof space does it need?

About 83 m² (893 sq ft) for 28 panels of 550 W, including a 15% allowance for access and spacing.

How big a battery do I need for 2000 units a month?

2000 units a month is an average load of about 2.78 kW. Running that average load for 4 hours takes roughly 13.5 kWh of LiFePO₄ battery. Most homes back up only essential loads, which needs far less. Use the wizard to size your own backup.

Will the system cover all 2000 units every month?

On average yes, because it is sized to offset 2000 units. Summer months produce more than the average and winter months less, so you may export surplus in summer and import some units in winter.

More solar tools

Planning estimate, not an installation design. Results use average sun hours and standard loss assumptions. Real output varies by season, shading, tilt, temperature and equipment. Have a qualified installer verify sizing, protection, earthing and utility requirements before purchase.